1

Nehéz

Why do CO₂ refrigeration systems require special attention when separating liquid and oil?


CO₂ operates at high pressure, which increases the risk of compressor failure and leaks
CO₂ cannot be used in systems with sight glasses
CO₂ is flammable, so separators cannot be used
CO₂ does not require lubrication, so separators are unnecessary

2

Nehéz

What is the critical pressure of CO₂ (R744)?


Approximately 10 bar
Approximately 74 bar
Approximately 31 bar
Approximately 120 bar

3

Nehéz

What characterises the transcritical process in CO₂ systems?


Conventional condensation occurs
It is irrelevant to the operation of the system
The system operates above the critical point and the refrigerant does not condense in the conventional manner
It occurs only at low temperatures

4

Nehéz

What characterises the subcritical CO₂ process?


The absence of condensation
The absence of evaporation
Operation above the critical point
The conventional condensation process below the critical point

5

Nehéz

What is the log(p)-h diagram for CO₂ used for?


To regulate pressure
For analysing thermodynamic processes in a refrigeration system
To detect leaks
To measure temperature

6

Nehéz

What can be read from the log(p)-h graph?


Only the amount of refrigerant
Only the humidity
Pressure, enthalpy, temperature and state of the refrigerant
Only the temperature

7

Nehéz

What are CO₂ saturation tables used for?


To determine the relationship between temperature and pressure at saturation
To determine the oil quantity
To measure humidity
To regulate the compressor

8

Nehéz

What does the CO₂ saturation state mean?


Equilibrium between the liquid and vapour phases
A state of high pressure
Dry ice state
A state in which the refrigerant is only a gas

9

Nehéz

When can dry ice (solid CO₂) form?


In the event of a sudden drop in pressure and temperature below the triple point
During normal operation of the system
At high temperature
At high pressure

10

Nehéz

What risks are associated with the formation of dry ice in a CO₂ system?


Pressure reduction
Improved efficiency
Blocked pipes and system damage
No risk

11

Nehéz

How does the CO₂ pressure change as the temperature rises?


It first decreases, then increases
It remains the same
Rises sharply
It decreases

12

Nehéz

Why is understanding the log(p)-h graph particularly important for CO₂?


It is only used for design purposes
As CO₂ systems operate in different modes (sub- and transcritical) and require detailed analysis
It only applies to NH₃
It doesn’t matter

13

Nehéz

What happens to CO₂ above the critical point?


It turns into a liquid
It turns into a solid
It ceases to conduct heat
It transitions to a supercritical state (no distinction between liquid and gas)

14

Nehéz

Why do CO₂ systems require precise pressure control?


Due to low pressures
Because there are no valves
Due to significant pressure changes with temperature fluctuations
They do not require control

15

Nehéz

What is the main characteristic of R744 (CO₂) refrigeration systems?


Low energy efficiency
No need for regulation
Low operating pressures
Very high operating pressures

16

Nehéz

What are the requirements for piping materials in CO₂ systems?


They must be able to withstand high pressures (e.g. high-grade steel)
They must be made exclusively from plastics
They may be made of any material
It does not matter

17

Nehéz

How does a booster system work in CO₂ installations?


It utilises two stages of compression (low and medium pressure) in a single system
It is used to store the refrigerant
It reduces the amount of refrigerant
It reduces the pressure in the evaporator

18

Nehéz

What is the function of high-pressure control valves in CO₂ systems?


They control the pressure on the high-pressure side and optimise system operation
They lower the evaporator temperature
They are used to store the refrigerant
They regulate oil flow

19

Nehéz

Why is pressure optimisation in CO₂ systems crucial?


It doesn’t matter
It enables the system to achieve maximum energy efficiency
It reduces the amount of refrigerant
It reduces the ambient temperature

20

Nehéz

What role do parallel-operating compressors play in CO₂ systems?


They increase energy consumption
They enable gas recovery from the medium-pressure stage and improve efficiency
They lower the ambient temperature
It does not matter

21

Nehéz

How does an ejector work in a CO₂ system?


Stores the refrigerant
It lowers the evaporator temperature
It uses the energy of the higher-pressure refrigerant to raise the pressure of the refrigerant from the lower stage, which improves efficiency
It increases the amount of refrigerant

22

Nehéz

What is the function of liquid ejectors in CO₂ systems?


They raise the refrigerant temperature
They assist with liquid recovery and improve evaporator feed
They increase the amount of oil
They reduce atmospheric pressure

23

Nehéz

What are the characteristics of partially flooded systems in CO₂ systems?


Lack of regulation
The presence of liquid in the evaporator, which improves heat transfer and efficiency
The absence of liquid in the evaporator
Low operating pressure

24

Nehéz

What is the main risk associated with static pressure in CO₂ systems?


A decrease in refrigerant quantity
A rise in pressure resulting from the refrigerant heating up whilst at rest
A drop in temperature
Increased efficiency

25

Nehéz

How can standstill pressure in CO₂ systems be reduced?


By increasing the temperature
By using parallel compressors and external cooling systems
By shutting down the system completely
By increasing the refrigerant charge

26

Nehéz

What does ‘stagnation’ of a refrigeration system mean in the context of CO₂?


Normal system operation
A drop in temperature
Improved efficiency
A lack of refrigerant flow, which can lead to increased pressure and safety risks

27

Nehéz

Why do CO₂ systems require more advanced automation than traditional systems?


They do not require automation
Due to low pressures
Because there are no valves
Due to the need for precise control of pressure and temperature

28

Nehéz

Which safety class applies to R744?


A1
B2L
A3
A2

29

Nehéz

In an R744 system operating in supercritical mode, the refrigerant entering the evaporator expansion valve is...


Saturated vapour at intermediate pressure
A two-phase mixture at intermediate pressure
A supercritical fluid
A subcooled liquid

30

Nehéz

In R744 supercritical systems, the gas cooler outlet valve controls:


The pressure in the gas cooler
The inlet temperature to the gas cooler
The gas cooler fans
The outlet temperature of the gas cooler

31

Nehéz

What is the main reason for using K65 copper tubing in some R744 systems?


They can withstand higher pressures
They bend easily
They come in a wider range of diameters
They have good low-temperature performance

32

Nehéz

Which of the following statements is correct regarding the installation of Schrader valves?


When brazing the valve body to the system, the core must be removed, then refitted and tightened to the correct torque
All Schrader valve cores are suitable for all refrigerants
Schrader valves must not be used in R744 systems
Hydrocarbons leak through Schrader valves

33

Nehéz

Which refrigerant can be detected using phenolphthalein paper?


R1234ze
R744
R717
R1270

34

Nehéz

How does a refrigerant shortage affect the high-pressure side of the system (without discharge pressure regulation)?


Discharge pressure will be lower, subcooling will be higher
Discharge pressure will be higher, and the degree of subcooling will be higher
The discharge pressure will be lower, and the subcooling will be lower
Discharge pressure will be higher, and the degree of subcooling will be lower

35

Nehéz

What is the benefit of using helium as a tracer gas in nitrogen during a pressure test?


It has a higher pressure than pure nitrogen
It is non-flammable
It has smaller molecules and diffuses more easily
It has a distinct odour

36

Nehéz

Why should an R744 system that has been drained be initially charged with the refrigerant in gaseous form?


To prevent damage to the compressor
To prevent the drain valve from opening
To ensure that R744 is charged slowly
To prevent the formation of dry ice

37

Nehéz

If an R744 system contains moisture because it has not been properly drained, what is the likely consequence?


Reduced cooling capacity
Excessively high discharge pressure
The formation of carbonic acid, which will cause damage to the system
The formation of hydrogen fluoride, which will decompose into hydrofluoric acid and damage the compressor

38

Nehéz

The pressure of R744 at a saturation temperature of 20 °C is approx.


90 bar g
14 bar g
25 bar g
56 bar g

39

Nehéz

At an ambient temperature of 25°C, the standby pressure in the low-pressure stage of an R744 cascade system will typically be…


The same as the high-pressure setting on the pressure switch
27.5 bar g
Higher than the maximum permissible pressure in the low-pressure stage
The same as the pressure set on the relief valve

40

Nehéz

What is the correct definition of critical temperature?


The temperature at which the vapour pressure of a liquid is equal to the ambient pressure surrounding the liquid
The temperature at which a substance changes from a gaseous to a solid state
The temperature above which there are no distinct liquid and gaseous phases
The temperature at which, for certain substances, electrical resistance is zero

41

Nehéz

In a supercritical system, under supercritical conditions, the working fluid in the gas cooler


it loses heat when its pressure drops
it loses heat as its temperature drops
loses heat during a phase change
loses heat at constant temperature and pressure